RESUMO

A major design objective of portable mass spectrometers is the ability to perform in situ chemical analysis on target samples in their native states in the undisturbed environment. The miniature instrument described here is fully contained in a wearable backpack (10 kg) with a geometry-independent low-temperature plasma (LTP) ion source integrated into a hand-held head unit (2 kg) to allow direct surface sampling and analysis. Detection of chemical warfare agent (CWA) simulants, illicit drugs, and explosives is demonstrated at nanogram levels directly from surfaces in near real time including those that have complex geometries, those that are heat-sensitive, and those bearing complex sample matrices. The instrument consumes an average of 65 W of power and can be operated autonomously under battery power for ca. 1.5 h, including the initial pump-down of the manifold. The maximum mass-to-charge ratio is 925 Th with mass resolution of 1-2 amu full width at half-maximun (fwhm) across the mass range. Multiple stages of tandem analysis can be performed to identify individual compounds in complex mixtures. Both positive and negative ion modes are available. A graphical user interface (GUI) is available for novice users to facilitate data acquisition and real-time spectral matching.


Assuntos
Espectrometria de Massas/métodos , Miniaturização , Software , Interface Usuário-Computador
2.
J Org Chem ; 77(6): 2819-28, 2012 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-22321002

RESUMO

As part of a comprehensive investigation on the stereochemical aspects of base-catalyzed 1,2-elimination reactions, we have studied a set of acyclic carbonyl substrates that react by an irreversible E1cB mechanism with largely anti stereospecificity. (2)H NMR data show that these reactions using KOH in EtOH/H(2)O under non-ion-pairing conditions produce a minimum of 85-89% anti elimination on stereospecifically labeled tert-butyl (2R*,3R*)- and (2R*,3S*)-3-(3-trifluoromethylphenoxy)-2,3-(2)H(2)-butanoate, S-tert-butyl (2R*,3R*)- and (2R*,3S*)-3-(3-trifluoromethylphenoxy)-2,3-(2)H(2)-butanethioate, and the related ketones, (4R*,5R*)- and (4R*,5S*)-5-(3-trifluoromethylphenoxy)-4,5-(2)H(2)-3-hexanone. With both diastereomers of each substrate available, the KIEs can be calculated and the innate stereoselectivities determined. The elimination reactions of the ß-3-trifluoromethylphenoxy substrates occur by E1cB mechanisms with diffusionally equilibrated enolate-anion intermediates. Thus, it is clear that anti elimination does not depend solely upon concerted E2 mechanisms. Negative hyperconjugation provides a satisfactory explanation for the anti stereospecificity exhibited by our carbonyl substrates, where the leaving group activates the anti proton, leading to the enolate intermediate. The activation of the anti proton by negative hyperconjugation may also play a role in the concerted pathways of E2 mechanisms. We have also measured the rates of the hydroxide-catalyzed elimination reactions of butanoate, thiobutanoate, and ketone substrates in EtOH/H(2)O, with ß-tosyloxy, acetoxy, and 3-trifluoromethylphenoxy nucleofuges.


Assuntos
Ésteres/química , Cetonas/química , Éteres Fenílicos/química , Compostos de Sulfidrila/química , Compostos de Tosil/química , Catálise , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Prótons , Estereoisomerismo
3.
Rapid Commun Mass Spectrom ; 25(10): 1437-44, 2011 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-21504010

RESUMO

Vapors of four chemical warfare agent (CWA) stimulants, 2-chloroethyl ethyl sulfide (CEES), diethyl malonate (DEM), dimethyl methylphosphonate (DMMP), and methyl salicylate (MeS), were detected, identified, and quantitated using a fully automated, field-deployable, miniature mass spectrometer. Samples were ionized using a glow discharge electron ionization (GDEI) source, and ions were mass analyzed with a cylindrical ion trap (CIT) mass analyzer. A dual-tube thermal desorption system was used to trap compounds on 50:50 Tenax TA/Carboxen 569 sorbent before their thermal release. The sample concentrations ranged from low parts per billion [ppb] to two parts per million [ppm]. Limits of detection (LODs) ranged from 0.26 to 5.0 ppb. Receiver operating characteristic (ROC) curves are presented for each analyte. A sample of CEES at low ppb concentration was combined separately with two interferents, bleach (saturated vapor) and diesel fuel exhaust (1%), as a way to explore the capability of detecting the simulant in an environmental matrix. Also investigated was a mixture of the four CWA simulants (at concentrations in air ranging from 270 to 380 ppb). Tandem mass (MS/MS) spectral data were used to identify and quantify the individual components.


Assuntos
Ar/análise , Substâncias para a Guerra Química/análise , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos , Substâncias para a Guerra Química/isolamento & purificação , Malonatos/análise , Malonatos/isolamento & purificação , Miniaturização , Modelos Químicos , Gás de Mostarda/análogos & derivados , Gás de Mostarda/análise , Gás de Mostarda/isolamento & purificação , Compostos Organofosforados/análise , Compostos Organofosforados/isolamento & purificação , Curva ROC , Salicilatos/análise , Salicilatos/isolamento & purificação , Sensibilidade e Especificidade
4.
Analyst ; 136(1): 120-7, 2011 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-20976316

RESUMO

Gaseous ammonia, a common toxic industrial compound, is not detected readily in ion trap mass spectrometers because its molecular ion falls below the low-mass cutoff (~m/z 40) normally used when examining organic compounds. Instead, reactions of ammonia with halobenzene radical cations were used with internal electron ionization in two cylindrical ion trap miniature mass spectrometers to create a characteristic product ion by which to identify and quantify ammonia. Ammonia showed a linear response over the concentration range studied (parts per million [ppm] to parts per billion [ppb]) with limits of detection of 17 ppm and 220 ppb for experiments involving direct introduction and thermal desorption after pre-concentration, respectively. These values are comparable to ammonia's permissible exposure limit (50 ppm) and odor threshold (5 ppm). Receiver operating characteristic (ROC) curves were used to describe the method sensitivity, the probability of true positives, and the false positive rate for ammonia. A customized reaction scan function was created to select the species available for the ion/molecule reaction and set the amount of time the product ion could be accumulated in the trap. Product ion identity was verified using tandem mass spectrometry. Similar reactions with methylamine, ethylamine and the two nitriles, acetonitrile and benzonitrile, were explored.


Assuntos
Amônia/análise , Íons/química , Espectrometria de Massas em Tandem/métodos , Aminas/química , Bromobenzenos/química , Clorobenzenos/química , Miniaturização , Nitrilas/química
5.
Analyst ; 135(5): 994-1003, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20419248

RESUMO

Gaseous samples of nine toxic industrial compounds (acrolein, acrylonitrile, carbon disulfide, cyanogen chloride, ethylene oxide, formaldehyde, hydrogen cyanide, phosgene, and sulfur dioxide) were detected, identified, and quantitated using a fully automated, fieldable, miniature mass spectrometer equipped with a glow discharge electron ionization source and a cylindrical ion trap mass analyzer. The instrument was outfitted with a combined direct air leak and dual thermal desorption tube inlet that allowed for continuous sampling of compounds with throughput times of 2 min or less. Most compounds showed a linear response over the concentration ranges studied (sub-parts per billion [ppb] to parts per million [ppm]). Sorbent tube limits of detection (20 ppb to 8 ppm for all analytes) were lower than those reported for the two compounds examined using direct leak (acrylonitrile 16 ppm and phosgene 500 ppb). All limits of detection were below the concentration at which the compound poses an immediate danger to life and health. Sensitivity, probability of true positives, and the false positive rate for each analyte were investigated and described using receiver operating characteristic (ROC) curves. High quality data with low false positive and negative rates are indicative of the good chemical specificity and sensitivity of the instrument. Complex matrices consisting of second-hand smoke, gasoline exhaust, diesel fuel exhaust, and multiple analytes were also studied. Detection limits for analytes generally increased in the mixtures, but analytes were still detected at concentrations as low as 100 ppb.


Assuntos
Poluentes Atmosféricos/análise , Resíduos Industriais/análise , Espectrometria de Massas/instrumentação , Poluentes Atmosféricos/química , Poluentes Atmosféricos/toxicidade , Monitoramento Ambiental , Gases/química , Limite de Detecção , Espectrometria de Massas/métodos , Miniaturização
6.
Artigo em Inglês | MEDLINE | ID: mdl-20065521

RESUMO

A recently developed hand-held, rectilinear ion trap mass spectrometer, capable of performing in situ analysis, has been evaluated for a variety of environmentally relevant analytes. Different sampling and ionization methods were implemented, demonstrating the considerable versatility of this instrument. A discontinuous (viz. pulsed) atmospheric pressure inlet (DAPI) was used to introduce externally-generated analyte ions. Nitro compounds were ionized by electrosonic spray ionization (ESSI) yielding the protonated and sodiated forms of the molecular ion, as well as fragment ions. The amines 2,2,6,6-tetramethylpiperidine, triethylamine and 2,6-diphenylpyridine showed low parts per billion (ppb) detection limits. Vapor phase external ionization was used to examine the chemical warfare simulant dimethyl methylphosphonate and the insect repellant N,N-diethyl-m-toluamide. Membrane introduction mass spectrometry (MIMS) was used as the introduction system for hydrophobic analytes using a selectively permeable (polydimethylsiloxane) membrane placed within the vacuum manifold with subsequent ionization of the thermally desorbed neutral compounds inside the ion trap. MIMS allowed the quantitation of trace levels (a few ppb) of fluorinated compounds in the vapor phase. MIMS was also applied to the quantitation of aqueous polycyclic aromatic hydrocarbons (PAH's) with limits of detection again in the low ppb range for naphthalene, acenaphthene, anthracene and phenanthrene.

7.
Anal Chem ; 81(7): 2421-5, 2009 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19281190

RESUMO

For field applications, "miniature" and "rapid" have become almost synonymous, yet these small mass spectrometers are not useful if performance is too severely compromised. (To listen to a podcast about this feature, please go to the Analytical Chemistry website at pubs.acs.org/journal/ancham .).

8.
J Am Soc Mass Spectrom ; 20(8): 1397-404, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19299166

RESUMO

A method is described to improve resolution and peak shape in the Orbitrap under certain experimental conditions. In these experiments, an asymmetric anharmonic axial potential was first produced in the Orbitrap by detuning the voltage on the compensator electrode, which results in broad and multiply split mass spectral peaks. An AC waveform applied to the outer electrode, 180 degrees out of phase with ion axial motion and resonant with the frequency of ion axial motion, caused ions of a given m/z to be de-excited to the equator (z = 0) and then immediately re-excited. This process, termed "rephasing," leaves the ion packet with a narrower axial spatial extent and frequency distribution. For example, when the Orbitrap axial potential is thus anharmonically de-tuned, a resolution of 124,000 to 171,000 is obtained, a 2- to 3-fold improvement over the resolution of 40,000 to 60,000 without rephasing, at 10 ng/microL reserpine concentration. Such a rephasing capability may ultimately prove useful in implementing tandem mass spectrometry (MS/MS) in the Orbitrap, bringing the Orbitrap's high mass accuracy and resolution to bear on both the precursor and product ions in the same MS/MS scan and making available the collision energy regime of the Orbitrap, approximately 1500 eV.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Analyst ; 133(11): 1532-40, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18936830

RESUMO

Desorption electrospray ionization (DESI) is applied to the rapid, in-situ, direct qualitative and quantitative analysis of mixtures of explosives and drugs from a variety of fabrics, including cotton, silk, denim, polyester, rayon, spandex, leather and their blends. The compounds analyzed were explosives: trinitrohexahydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), 2,4,6-trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN) and the drugs of abuse: heroin, cocaine, and methamphetamine. Limits of detection are in the picogram range. DESI analyses were performed without sample preparation and carried out in the presence of common interfering chemical matrices, such as insect repellant, urine, and topical lotions. Spatial and depth profiling was investigated to examine the depth of penetration and lateral resolution. DESI was also used to examine cotton transfer swabs used for travel security sample collection in the screening process. High throughput quantitative analysis of fabric surfaces for targeted analytes is also reported.


Assuntos
Substâncias Explosivas/análise , Preparações Farmacêuticas/análise , Têxteis , Ciências Forenses/instrumentação , Ciências Forenses/métodos , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos
10.
Mass Spectrom Rev ; 27(6): 661-99, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18683895

RESUMO

Since its introduction, the orbitrap has proven to be a robust mass analyzer that can routinely deliver high resolving power and mass accuracy. Unlike conventional ion traps such as the Paul and Penning traps, the orbitrap uses only electrostatic fields to confine and to analyze injected ion populations. In addition, its relatively low cost, simple design and high space-charge capacity make it suitable for tackling complex scientific problems in which high performance is required. This review begins with a brief account of the set of inventions that led to the orbitrap, followed by a qualitative description of ion capture, ion motion in the trap and modes of detection. Various orbitrap instruments, including the commercially available linear ion trap-orbitrap hybrid mass spectrometers, are also discussed with emphasis on the different methods used to inject ions into the trap. Figures of merit such as resolving power, mass accuracy, dynamic range and sensitivity of each type of instrument are compared. In addition, experimental techniques that allow mass-selective manipulation of the motion of confined ions and their potential application in tandem mass spectrometry in the orbitrap are described. Finally, some specific applications are reviewed to illustrate the performance and versatility of the orbitrap mass spectrometers.


Assuntos
Desenho de Equipamento , Análise de Falha de Equipamento , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Avaliação da Tecnologia Biomédica , Espectrometria de Massas por Ionização por Electrospray/tendências
11.
Anal Chem ; 80(3): 734-41, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18181580

RESUMO

A miniature, handheld mass spectrometer, based on the rectilinear ion trap mass analyzer, has been applied to air monitoring for traces of toxic compounds. The instrument is battery-operated, hand-portable, and rugged. We anticipate its use in public safety, industrial hygiene, and environmental monitoring. Gaseous samples of nine toxic industrial compounds, phosgene, ethylene oxide, sulfur dioxide, acrylonitrile, cyanogen chloride, hydrogen cyanide, acrolein, formaldehyde, and ethyl parathion, were tested. A sorption trap inlet was constructed to serve as the interface between atmosphere and the vacuum chamber of the mass spectrometer. After selective collection of analytes on the sorbent bed, the sorbent tube was evacuated and then heated to desorb analyte into the instrument. Sampling, detection, identification, and quantitation of all compounds were readily achieved in times of less than 2 min, with detection limits ranging from 800 parts per trillion to 3 parts per million depending on the analyte. For all but one analyte, detection limits were well below (3.5-130 times below) permissible exposure limits. A linear dynamic range of 1-2 orders of magnitude was obtained over the concentration ranges studied (sub-ppbv to ppmv) for all analytes.

12.
Rapid Commun Mass Spectrom ; 21(22): 3729-36, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17952889

RESUMO

Novel sampling and detection methods using desorption electrospray ionization (DESI) are examined in the detection of explosives (RDX, TNT, HMX, and TNB) and agricultural chemicals (atrazine, alachlor and acetochlor) from aqueous matrices and authentic contaminated groundwater samples. DESI allows analysis of solid and liquid compounds directly from surfaces of interest with little or no sample preparation. Significant savings in analysis time and sample preparation are realized. The methods investigated here include (i) immediate analysis of filter paper wetted with contaminated water samples without further sample preparation, (ii) rapid liquid-liquid extraction (LLE), and (iii) analyte extraction from contaminated groundwater samples on-site using solid-phase extraction (SPE) membranes, followed by direct DESI analysis of the membrane. The wetted filter paper experiment demonstrates the maximum sample throughput for DESI analysis of aqueous matrices but has inadequate sensitivity for some of these analytes. Both the LLE and the SPE methods have adequate sensitivity. The resulting SPE membranes and/or small volume solvent extracts produced in these experiments are readily transported to off-site facilities for direct analysis by DESI. This realizes a significant reduction in the costs of sample shipping compared with those for typical liter-sized samples of groundwater. Total analysis times for these preliminary DESI analyses are comparable with or shorter than those for GC/MS and limits of detection approach environmental action levels for these compounds while maintaining a modest relative standard deviation. Tandem mass spectrometric data is used to provide additional specificity as needed.

13.
Anal Chem ; 79(20): 7734-9, 2007 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-17867653

RESUMO

The first coupling of atmospheric pressure ionization methods, electrospray ionization (ESI) and desorption electrospray ionization (DESI), to a miniature hand-held mass spectrometer is reported. The instrument employs a rectilinear ion trap (RIT) mass analyzer and is battery-operated, hand-portable, and rugged (total system: 10 kg, 0.014 m(3), 75 W power consumption). The mass spectrometer was fitted with an atmospheric inlet, consisting of a 10 cm x 127 microm inner diameter stainless steel capillary tube which was used to introduce gas into the vacuum chamber at 13 mL/min. The operating pressure was 15 mTorr. Ions, generated by the atmospheric pressure ion source, were directed by the inlet along the axis of the ion trap, entering through an aperture in the dc-biased end plate, which was also operated as an ion gate. ESI and DESI sources were used to generate ions; ESI-MS analysis of an aqueous mixture of drugs yielded detection limits in the low parts-per-billion range. Signal response was linear over more than 3 orders of magnitude. Tandem mass spectrometry experiments were used to identify components of this mixture. ESI was also applied to the analysis of peptides and in this case multiply charged species were observed for compounds of molecular weight up to 1200 Da. Cocaine samples deposited or already present on different surfaces, including currency, were rapidly analyzed in situ by DESI. A geometry-independent version of the DESI ion source was also coupled to the miniature mass spectrometer. These results demonstrate that atmospheric pressure ionization can be implemented on simple portable mass spectrometry systems.


Assuntos
Espectrometria de Massas/métodos , Alquilação , Calibragem , Estrutura Molecular , Peso Molecular , Pressão , Proteínas/química , Proteínas/metabolismo , Temperatura
14.
J Mass Spectrom ; 42(5): 675-80, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17441220

RESUMO

A glow discharge electron impact ionization (GDEI) source was developed for operation using air as the support gas. An alternative to the use of thermoemission from a resistively heated filament electron source for miniature mass spectrometers, the GDEI source is shown to have advantages of long lifetime under high-pressure operation and low power consumption. The GDEI source was characterized using our laboratory's handheld mass spectrometer, the Mini 10. The effects of the discharge voltage and pressure were investigated. Design considerations are illustrated with calculations. Performance is demonstrated in a set of experimental tests. The results show that the low power requirements, mechanical ruggedness, and quality of the data produced using the small glow discharge ion source make it well-suited for use with a portable handheld mass spectrometer.

15.
J Am Soc Mass Spectrom ; 18(6): 980-3, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17382556

RESUMO

The mass resolution achieved in selective ion isolation using resonance excitation is usually limited by the frequency resolution of the ac waveform and by unintended off-resonance excitation. A new method of phase-enhanced selective ion ejection based on broadband dipolar excitation and ion ejection applicable to the Orbitrap is described and shown to allow an isolation resolution of 28,400. The method is calculated to be able to provide a mass resolution for ion ejection of up to 100,000.

16.
Rapid Commun Mass Spectrom ; 20(22): 3403-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17051609

RESUMO

Desorption electrospray ionization (DESI) is implemented on an Orbitrap mass spectrometer. The ion source is described and applications which utilize the high-resolution capabilities of the Orbitrap are emphasized, including the characterization of peptides and active ingredients in pharmaceutical tablets. Measurements are made in less than 1 s at a resolution of 60,000. The implications of the data for the mechanisms of DESI are discussed.


Assuntos
Peptídeos/química , Preparações Farmacêuticas/química , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Bradicinina/química , Loratadina/química , Comprimidos
17.
Analyst ; 131(4): 556-67, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16568173

RESUMO

A portable tandem mass spectrometer, capable of performing atmospheric pressure chemical ionization (APCI) using a direct atmospheric inlet, is applied to the real-time monitoring of toxic compounds in air. Analytes of interest include dimethyl methylphosphonate, arsine, benzene, toluene, pyridine and vinyl acetate. The detection, identification and quantification of organic and inorganic compounds in air is demonstrated using short analysis times (<5 seconds) with detection limits in the low ppb (v/v) levels and linear dynamic ranges of several orders of magnitude. Highly specific detection and identification is achieved, even when the analyte is a trace component in a complex mixture including such interferents as fuels, lubricants, and cleaners. The effects of environmental conditions, including temperature and humidity, are delineated. Receiver operating characteristic (ROC) curves are presented to show the trade-off between false positive and false negative detection rates. Tandem mass spectrometry based both on collision-induced dissociation and on selective atmospheric pressure ion/molecule reactions is also used to increase selectivity and sensitivity.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Espectrometria de Massas/instrumentação , Venenos/análise , Monitoramento Ambiental/métodos , Desenho de Equipamento , Humanos , Espectrometria de Massas/métodos , Curva ROC
18.
Analyst ; 131(4): 579-89, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16568176

RESUMO

The suitability of atmospheric pressure chemical ionization mass spectrometry as sensing instrumentation for the real-time monitoring of low levels of toxic compounds is assessed, especially with respect to public safety applications. Gaseous samples of nine toxic industrial compounds, NH3, H2S, Cl2, CS2, SO2, C2H4O, HBr, C6H6 and AsH3, and two chemical warfare agent simulants, dimethyl methylphosphonate (DMMP) and methyl salicylate (MeS), were studied. API-MS proves highly suited to this application, with speedy analysis times (<30 seconds), high sensitivity, high selectivity towards analytes, good precision, dynamic range and accuracy. Tandem MS methods were implemented in selected cases for improved selectivity, sensitivity, and limits of detection. Limits of detection in the parts-per-billion and parts-per-trillion range were achieved for this set of analytes. In all cases detection limits were well below the compounds' permissible exposure limits (PELs), even in the presence of added complex mixtures of alkanes. Linear responses, up to several orders of magnitude, were obtained over the concentration ranges studied (sub-ppb to ppm), with relative standard deviations less than 3%, regardless of the presence of alkane interferents. Receiver operating characteristic (ROC) curves are presented to show the performance trade-off between sensitivity, probability of correct detection, and false positive rate. A dynamic sample preparation system for the production of gas phase analyte concentrations ranging from 100 pptr to 100 ppm and capable of admixing gaseous matrix compounds and control of relative humidity and temperature is also described.


Assuntos
Poluentes Atmosféricos/análise , Substâncias para a Guerra Química/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Humanos , Curva ROC , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos
19.
J Phys Chem A ; 110(8): 2682-9, 2006 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-16494379

RESUMO

A dipolar ac signal applied to the split outer electrode of an Orbitrap mass spectrometer at the axial resonance frequency causes excitation of ion axial motion and either eventual ion ejection from the trap, if applied in phase with ion motion, or de-excitation, if applied 180 degrees out of phase. Both de-excitation and excitation may be achieved mass-selectively. The extent of ion axial de-excitation depends on the ac amplitude and on the number of cycles applied; sufficient de-excitation can be accomplished such that the ion signal cannot be observed above baseline noise. After de-excitation, the ions remain trapped and in rapid orbital (but not axial) motion, which allows them to be re-excited coherently by application of a second ac waveform allowing the signal again to be observed. Both broad-band and narrow-band waveforms have been used to de-excite and to re-excite ion motion. Using narrow-band waveforms, selective de-excitation and re-excitation can be performed with unit mass selection, leaving an adjacent 13C isotopic peak unaffected. The origin and potential applications of these new capabilities is delineated.

20.
J Mass Spectrom ; 40(4): 430-43, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15838939

RESUMO

Research areas such as proteomics and metabolomics are driving the demand for mass spectrometers that have high performance but modest power requirements, size, and cost. This paper describes such an instrument, the Orbitrap, based on a new type of mass analyzer invented by Makarov. The Orbitrap operates by radially trapping ions about a central spindle electrode. An outer barrel-like electrode is coaxial with the inner spindlelike electrode and mass/charge values are measured from the frequency of harmonic ion oscillations, along the axis of the electric field, undergone by the orbitally trapped ions. This axial frequency is independent of the energy and spatial spread of the ions. Ion frequencies are measured non-destructively by acquisition of time-domain image current transients, with subsequent fast Fourier transforms (FFTs) being used to obtain the mass spectra. In addition to describing the Orbitrap mass analyzer, this paper also describes a complete Orbitrap-based mass spectrometer, equipped with an electrospray ionization source (ESI). Ions are transferred from the ESI source through three stages of differential pumping using RF guide quadrupoles. The third quadrupole, pressurized to less than 10(-3) Torr with collision gas, acts as an ion accumulator; ion/neutral collisions slow the ions and cause them to pool in an axial potential well at the end of the quadrupole. Ion bunches are injected from this pool into the Orbitrap analyzer for mass analysis. The ion injection process is described in a simplified way, including a description of electrodynamic squeezing, field compensation for the effects of the ion injection slit, and criteria for orbital stability. Features of the Orbitrap at its present stage of development include high mass resolution (up to 150,000), large space charge capacity, high mass accuracy (2-5 ppm), a mass/charge range of at least 6000, and dynamic range greater than 10(3). Applications based on electrospray ionization are described, including characterization of transition-metal complexes, oligosaccharides, peptides, and proteins. Use is also made of the high-resolution capabilities of the Orbitrap to confirm the presence of metaclusters of serine octamers in ESI mass spectra and to perform H/D exchange experiments on these ions in the storage quadrupole.


Assuntos
Espectrometria de Massas/instrumentação , Álcool Desidrogenase/química , Íons/química , Oligossacarídeos/química , Rotação , Serina/química
SELEÇÃO DE REFERÊNCIAS